25920 Eden Landing Road, Hayward, CA, United States of America, 94545
RFMCO represents Hexonic heat exchangers in CA and Northern NV, including shell & tube, brazed plate and frame heat exchangers for commercial applications
Hexonic is a family-owned company in Poland founded in 1988, manufacturing heat exchangers and pressure vessels. As of 2024, Hexonic assembles all its heat exchangers in South Carolina, allowing for shorter lead times to California and Nevada. And all heat exchangers are assembled in accordance with ASME codes.
Model HAD Shell & Coil Heat Exchangers
Easy installation
Saving space
Low operating costs
High efficiency
Made according to PED and ASME codes
Applications
HVAC systems
Steam applications
Heating and cooling systems
Heat exchange in industrial processes
Oil coolers
Working Parameters
Max. temperature: 482 ° F
Min. temperature: -4°F
Max. pressure: 363 PSI
Model H Shell & Coil Heat Exchangers
Saving space - compact size and vertical installation reduce space needs for installation
High efficiency - higher heat exchange coefficient from corrugated tubes that increase flow turbulence and intensify heat exchange
Made according to PED codes
Applications
HVAC systems
Steam applications
Food industry
Brewing industry
Beverage manufacturing
Oil manufacturing
Clean-In-Place (CIP) stations
Chemical industry
District cooling
Cooling systems
Working Parameters
Tubes
Max. temperature: 392°F
Max. pressure: 232 PSI
Shell
Max. temperature: 392°F
Max. pressure : 232 PSI
Model RAD Shell & Coil Heat Exchangers
Optimized for modern A2L refrigerants like r32, r452b, r454b and propane r290
Highly resistant to corrosion – made of high-alloy austenitic stainless steel
Easy assembly and small footprint
High thermal efficiency with high-performance superheating used with well, river, lake water
Even refrigerant distribution with low maldistribution risk
Manufactured in accordance with ASME, PED codes
Proven technology with thousands of units operating in the field
Applications
Ground source heat pumps
Working Parameters
Shell side (water)
Max. Pressure: 232 PSI
Max. Temperature: 392 °F
Coil side (refrigerant)
Max. Pressure: 652 PSI
Max. Temperature: 266 °F
Model DNA Shell & Tube Heat Exchangers
Significantly higher heat transfer rates comparing to standard solutions
More efficient operation in high volume applications (e.g. flue gas, hot air, low pressure steam)
High mechanical resistance
The construction enables to obtain smaller, much lighter and material saving device
Features
Effective turbulent and vortex flow
Increases heat transfer coefficient up to double values
Effective heat transfer area
Homogeneous distribution of flow and velocity field
Flexible tube bundle
Low pressure drop
No dead spots
Baffle-free
No need of shell compensator
Elimination of vibration
Large heat transfer area in compact construction
Ideal for high volume media
Applications
Low pressure steam condensers
Industrial and chemical processes
Recuperation and regeneration in industrial technologies
Waste heat recovery - diesel and gas engines, cogeneration
Water and steam systems, cooling circuits
Working Parameters
Max. temp.: 397°F /203°C
Min. temp.: -4°F /-20°C
Max. pressure: Shell side: 145 PSI /10 bar & Tubes side: 232 PSI /16 bar
Model P-Line Shell & Coil Heat Exchangers
Designed to operate in pharmaceutical production, meets the highest hygienic standards
3-A certified
Manufactured in accordance with cGMP, PED, ASME codes
Double tube sheet protect pharmaceutical products before mixing it with the other medium
Surfaces have been polished to Ra ≤ 0.5 µm roughness for precise cleaning
Made entirely of stainless steel
One, two or four-pass design
Horizontal and vertical models available
Applications
WFI generator
WFI hot storage and distribution
WFI cold storage and distribution
WFI point of use
Clean steam generation
Food industry
Diary industry
Brewing industry
Working Parameters
Tubes
Max. temperature: Viton: 284°F & Silicon: 249°F*
Min. Temperature: Viton: 1.4°F* & Silicon: -°F
Max. pressure: Viton: 145PSI & Silicon: 145PSI
Shell:
Max. Temperature: 392°F
Min. Temperature: -13°F
Max. Pressure: 145 PSI
Model JAG Plate Heat Exchangers
High thermal performance
Technical solutions facilitating the exchanger installation and operation
Select proper installation operating parameters using accurate heat plate sizing
Heating plates made of stainless steel or titanium
Dismountable design
Applications
Chemical industry
Food & bev industry
HVAC-R
Iron & steel industry
Pulp & paper industry
Marine industry
Power
Pharmaceutical industry
Technical Updates
Additionally corrugated distribution area is designed to enhance turbulent flow in the entrance part of the plate. It also allows even flow through the plate which increases heat transfer by optimal use of its surface area. Specifically corrugated distribution area strengthens the plate and increases the stability of the whole construction. Carefully designed groove together with specially modelled gasket makes the exchanger withstand high pressure.
Triple Plate Positioning System Features
Gasket aligning system – special protruding
Elements align the plates in relation to one another
Point locking system – dedicated corrugated
Elements on the plate
Stellar suspending system – alignment in position to the upper and lower bar
The Finite Element Method Analysis (FEM) optimized the design of the JAG plate heat exchanger in terms of strength, mainly by improving the stress distribution on the cover plates and modifying the location of the fasteners, which contributed to the extension of the operating parameters.
Gaskets Patented Hybrid Lock System
Lock-in method
Lock-on method
Optimized unique shape of the gasket
Highest production standards
Model JAG Plate Heat Exchanger Design
Metal roller
Connection size: DN32 to DN250
Special profile of carrying bar
Front and rear plate available in various colors
Additional front feet
Sliding sleeve
Lock washer
Other frame elements made of galvanized or stainless steel
U-LEG
Model JAG Plate Heat Exchanger Working Parameters
Max. pressure: 150, 250, 300, 400 PSI
Max. temperature: 300˚F
Min. temperature: -4˚F
Model ST Tube-in-Tube Heat Exchangers
ST tube-in-tube heat exchangers find their application where fluids of high viscosity, density or high fiber or solid particle contamination are subjected to heat treatment, e.g. at wastewater treatment plants.
Applications
Dismountable design
Option to increase heat exchange surface
Stainless steel make
Broad range
Tube-in-Tube Features
The single section of the ST exchanger consists of two tubes with different nominal diameters.
The tube with smaller diameter (product side) is installed inside the tube with the larger diameter (shell side).
Hexonic heat exchangers offer efficient heat transfer utilizing fewer resources. Customers around the world have reduced costs, saved time and made a positive impact on the environment using Hexonic heat exchangers.
Contact us for Hexonic heat exchangers in California: https://www.rfmacdonald.com/contact/
R.F. MacDonald Co. has been in the business of supplying and servicing boilers and pumps to industrial and commercial customers in California and Nevada for over 50 years.
SALES OF BOILER AND PUMP EQUIPMENT
For your convenience we maintain sales and service offices in a number of strategic locations in California and Nevada. Our experienced technical sales staff will carefully evaluate your needs and provide custom equipment solutions with reliability and process improvement in mind. We represent the highest quality equipment manufacturers in the industry to ensure we are providing the most efficient and environmentally clean equipment available. Some of our boiler brands include Cleaver Brooks, Fulton, Camus, CB Natcom and some of our pump brands include ITT Goulds, Grundfos, Seepex, G&L Pumps and Blackmer and many others.
SERVICE AND INSTALLATION
Our factory trained and certified technicians repair all makes and models of boilers. We also provide in-house fabrication services for assembling boiler packages and custom systems into pre-piped and wired skids, simplifying field installation requirements. Our field services include troubleshooting, repair, certified welding, operator training, and installation. We believe in servicing what we sell, 24 hours a day, 7 days a week. With a large fleet of service trucks on the road, we provide full field service capabilities from all locations.
EXTENSIVE PARTS INVENTORY
Our huge boiler and boiler parts inventory combined with our multiple locations ensures fast and reliable service anytime day or night. Boilers are also available for temporary requirements.
OTHER SPECIALTY SERVICES
We offer many special services for customers such as parts, Mobile and Rental Boilers, Boiler and Pump Training and a growing Ultra Low NOx knowledge bank on our website at www.rfmacdonald.com.
We would be honored to serve your needs.
Title | Name | Phone | Extension | |
---|---|---|---|---|
San Francisco Headquarters | info@rfmacdonald.com | 510-784-0110 | ||
Los Angeles Office | 714-257-0900 | |||
Modesto Office | 209-576-0726 | |||
San Diego Office | 858-538-5877 | |||
Fresno Office | 559-498-6949 | |||
Solano/Napa Office | 707-586-9234 | |||
Las Vegas Office | 702-220-6680 | |||
Reno Office | 775-356-0300 | |||
Bakersfield | 661-363-6225 |
Locations | Address | State | Country | Zip Code |
---|---|---|---|---|
R.F. MacDonald Co. | 25920 Eden Landing Road, Hayward | CA | United States of America | 94545 |